--  Title:    DPS_V41.MIB
--  Version:  v4.1
--
--  Copyright @ 1997-2004 DPS Inc. All Rights Reserved
--
--  This MIB defines objects for the DPS products.
--
--

DPS-MIB-V38 DEFINITIONS ::= BEGIN

IMPORTS
	DisplayString,
	sysDescr,
	sysLocation
		FROM RFC1213-MIB
	OBJECT-TYPE
		FROM RFC1212-MIB
	enterprises
		FROM RFC1155-SMI
	TRAP-TYPE
		FROM RFC-1215;

dpsInc OBJECT IDENTIFIER ::= {enterprises  2682}

dpsAlarmControl OBJECT IDENTIFIER ::= {dpsInc 1}

tmonXM OBJECT IDENTIFIER ::= {dpsAlarmControl 1}

tmonIdent OBJECT IDENTIFIER ::= {tmonXM 1}

tmonIdentManufacturer OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The TMON/XM Unit manufacturer."
	::= {tmonIdent  1}

tmonIdentModel OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The TMON/XM model designation."
	::= {tmonIdent  2}

tmonIdentSoftwareVersion OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The TMON/XM SNMP Agent software version."
	::= {tmonIdent  3}

tmonAlarmTable OBJECT-TYPE
	SYNTAX  SEQUENCE OF TMonAlarmEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "A table of TMon Alarm-specific information."
	::= {tmonXM 2}

tmonAlarmEntry OBJECT-TYPE
	SYNTAX  TMonAlarmEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Information about a particular TMon alarm."
	INDEX   {tmonAIndex}
	::= {tmonAlarmTable 1}

TMonAlarmEntry ::= SEQUENCE	{	tmonAIndex		INTEGER,
					tmonASite		DisplayString,
					tmonADesc		DisplayString,
					tmonAState		DisplayString,
					tmonASeverity		DisplayString,
					tmonAChgDate		DisplayString,
					tmonAChgTime		DisplayString,
					tmonAAuxDesc 		DisplayString,
					tmonADispDesc		DisplayString,
					tmonAPntType		INTEGER,
					tmonAPort		INTEGER,
					tmonAAddress		INTEGER,
					tmonADisplay		INTEGER,
					tmonAPoint		INTEGER,
               tmonAIPAddr 		DisplayString,
					tmonADevDesc		DisplayString
				}

tmonAIndex OBJECT-TYPE
	SYNTAX  INTEGER (0..2147483647)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Tmon alarm table index (1..NumberOfAlarms)."
	::={tmonAlarmEntry 1}

tmonASite OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The site of the alarm (i.e. Atlanta Hub, Sub-Station H32)."
	::= {tmonAlarmEntry 2}

tmonADesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "A user-defined text string associated with the alarm 
					 (i.e. South Door, Generator, Power Grid 1)."
	::= {tmonAlarmEntry 3}

tmonAState OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The current alarm state."
	::= {tmonAlarmEntry 4}

tmonASeverity OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The severity of the last alarm event."
	::= {tmonAlarmEntry 5}

tmonAChgDate OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The date (mm/dd/yy) of the last alarm event."
	::= {tmonAlarmEntry 6}

tmonAChgTime OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The time (hh:mm:ss) of the last alarm event."
	::= {tmonAlarmEntry 7}

tmonAAuxDesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "An auxiliary user-defined text string associated with the
					 alarm (i.e. This remote needs servicing)."
	::= {tmonAlarmEntry 8}

tmonADispDesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "A description of the display on which this point appears."
	::= {tmonAlarmEntry 9}

tmonAPntType OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Type of this point."
	::={tmonAlarmEntry 10}

tmonAPort OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Port on which this point is reported."
	::={tmonAlarmEntry 11}

tmonAAddress OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Address of unit reporting this point."
	::={tmonAlarmEntry 12}

tmonADisplay OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Display on which this point appears."
	::={tmonAlarmEntry 13}

tmonAPoint OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Index into display of this point."
	::={tmonAlarmEntry 14}

tmonAIPAddr OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The IP Address of the device on which this point appears."
	::= {tmonAlarmEntry 16}
   
tmonADevDesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "A description of the device on which this point appears."
	::= {tmonAlarmEntry 17}

-- structure used to issue a command to tmonXM element

tmonCommandGrid OBJECT IDENTIFIER ::= {tmonXM 3}

tmonCPType OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon point type."
	::= {tmonCommandGrid 1}

tmonCPort OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon port number."
	::= {tmonCommandGrid 2}

tmonCAddress OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon_port address number."
	::= {tmonCommandGrid 3}

tmonCDisplay OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon_port_address display number."
	::= {tmonCommandGrid 4}

tmonCPoint OBJECT-TYPE
	SYNTAX  INTEGER (1..64)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon_port_display point number (1-64)."
	::= {tmonCommandGrid 5}

tmonCEvent OBJECT-TYPE
	SYNTAX  INTEGER
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Tmon event ID."
	::= {tmonCommandGrid 6}

tmonCAction OBJECT-TYPE
	SYNTAX  INTEGER {	latch(1),
				release(2),
				momentary(3),
				ack(17),
				tag(18),
				untag(19)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Requested command action (tmonXM will ignore if invalid)."
	::= {tmonCommandGrid 7}

tmonCAuxText OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "An auxiliary user-defined text string associated with the
					 command (i.e. User_initials)."
	::= {tmonCommandGrid 8}

tmonCResult OBJECT-TYPE
	SYNTAX  INTEGER {	success(1),
				failure(2),
				pending(3)
			}
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Command result."
	::= {tmonCommandGrid 9}



dpsRTU OBJECT IDENTIFIER ::= {dpsAlarmControl 2}

dpsRTUIdent OBJECT IDENTIFIER ::= {dpsRTU 1}

dpsRTUManufacturer OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The Remote Telemetry Unit manufacturer."
	::= {dpsRTUIdent  1}

dpsRTUModel OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The RTU model designation."
	::= {dpsRTUIdent  2}

dpsRTUFirmwareVersion OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The RTU firmware version."
	::= {dpsRTUIdent  3}

dpsRTUDateTime OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "The RTU system date and time."
	::= {dpsRTUIdent  4}

dpsRTUSyncReq OBJECT-TYPE
	SYNTAX  INTEGER {	sync(1)
			}
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Caution: SETting this object initiates traps for all
					 standing alarms."
	::= {dpsRTUIdent  5}


-- structure used to access displays managed by this RTU

dpsRTUDisplayGrid OBJECT-TYPE
	SYNTAX  SEQUENCE OF DPSrtuDispEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Holds information on displays managed by the RTU."
	::= {dpsRTU 2}

dpsRTUDisplayEntry OBJECT-TYPE
	SYNTAX  DPSrtuDispEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Information about a particular RTU display."
	INDEX   {dpsRTUPort, dpsRTUAddress, dpsRTUDisplay}
	::= {dpsRTUDisplayGrid 1}

DPSrtuDispEntry ::= SEQUENCE {	dpsRTUPort		INTEGER,
					dpsRTUAddress		INTEGER,
					dpsRTUDisplay		INTEGER,
					dpsRTUDispDesc		DisplayString,
					dpsRTUPntMap		DisplayString
				}

dpsRTUPort OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU port number."
	::= {dpsRTUDisplayEntry 1}

dpsRTUAddress OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU_port address number."
	::= {dpsRTUDisplayEntry 2}

dpsRTUDisplay OBJECT-TYPE 
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU_port_address display number."
	::= {dpsRTUDisplayEntry 3}

dpsRTUDispDesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "A description of the associated display."
	::= {dpsRTUDisplayEntry 4}

dpsRTUPntMap OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "A map of the points appearing in this display."
	::= {dpsRTUDisplayEntry 5}


-- structure used to issue a control to a managed point

dpsRTUControlGrid OBJECT IDENTIFIER ::= {dpsRTU 3}

dpsRTUCPort OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "RTU port number."
	::= {dpsRTUControlGrid 1}

dpsRTUCAddress OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "RTU_port address number."
	::= {dpsRTUControlGrid 2}

dpsRTUCDisplay OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "RTU_port_address display number."
	::= {dpsRTUControlGrid 3}

dpsRTUCPoint OBJECT-TYPE
	SYNTAX  INTEGER (1..64)
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "RTU_port_display point number (1-64)."
	::= {dpsRTUControlGrid 4}

dpsRTUCAction OBJECT-TYPE
	SYNTAX  INTEGER {	latch(1),
				release(2),
				momentary(3)
			 }
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "Requested action on point (RTU will ignore if invalid)."
	::= {dpsRTUControlGrid 5}

dpsRTUAlarmGrid OBJECT-TYPE
	SYNTAX  SEQUENCE OF DPSrtuAlarmEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Holds individual alarm point information."
	::= {dpsRTU 5}

dpsRTUAlarmEntry OBJECT-TYPE
	SYNTAX  DPSrtuAlarmEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Detailed information about a particular RTU display."
	INDEX   {dpsRTUAPort, dpsRTUAAddress, dpsRTUADisplay, dpsRTUAPoint}
	::= {dpsRTUAlarmGrid 1}

DPSrtuAlarmEntry ::= SEQUENCE	 {	dpsRTUAPort		INTEGER,
					dpsRTUAAddress		INTEGER,
					dpsRTUADisplay		INTEGER,
					dpsRTUAPoint		INTEGER,
					dpsRTUAPntDesc		DisplayString,
					dpsRTUAState		DisplayString
				}

dpsRTUAPort OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU port number."
	::= {dpsRTUAlarmEntry 1}

dpsRTUAAddress OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU_port address number."
	::= {dpsRTUAlarmEntry 2}

dpsRTUADisplay OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU_port_address display number."
	::= {dpsRTUAlarmEntry 3}

dpsRTUAPoint OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "RTU_port_address_display point number."
	::= {dpsRTUAlarmEntry 4}

dpsRTUAPntDesc OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-write
	STATUS  mandatory
	DESCRIPTION "A description of this point."
	::= {dpsRTUAlarmEntry 5}

dpsRTUAState OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The current state of this point."
	::= {dpsRTUAlarmEntry 6}

--Table for accessing analog channel value

analogChannels OBJECT-TYPE
	SYNTAX  SEQUENCE OF ChannelEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Holds information on analog channels"
	::= {dpsRTU 6}

channelEntry OBJECT-TYPE
	SYNTAX  ChannelEntry
	ACCESS  not-accessible
	STATUS  mandatory
	DESCRIPTION "Information about a particular channel"
	INDEX   {channelNumber}
	::= {analogChannels 1}

ChannelEntry ::= SEQUENCE 	{	channelNumber		INTEGER,
					enabled			INTEGER,
					description		DisplayString,
					value			DisplayString,
					thresholds		INTEGER
				}

channelNumber OBJECT-TYPE
	SYNTAX  INTEGER (0..999)
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Input channel number"
	::= {channelEntry 1}

enabled OBJECT-TYPE
	SYNTAX  INTEGER { 	disabled	(0),
				enabled		(1)
			}		
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Enable status of channel"
	::= {channelEntry 2}

description OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The user defined description of the channel"
	::= {channelEntry 3}		
										
value OBJECT-TYPE
	SYNTAX  DisplayString
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "The current value of the channel"
	::= {channelEntry 4}		

thresholds OBJECT-TYPE
	SYNTAX  INTEGER { 	noAlarms	(0),
				minorUnder	(1),
				minorOver	(2),
				majorUnder	(3),
				majorOver	(4),
				notDetected (5)
			}		
	ACCESS  read-only
	STATUS  mandatory
	DESCRIPTION "Highest threshold level crossed, if MJ, MN is assumed"
	::= {channelEntry 5}
	
-- TRAP definitions

tmonCRalarmSet TRAP-TYPE
	ENTERPRISE	tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a critical alarm is set."
	::= 10

tmonCRalarmClr TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc } 
	DESCRIPTION "Generated when a critical alarm clears."
	::= 11

tmonMJalarmSet TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a major alarm is set."
	::= 12

tmonMJalarmClr TRAP-TYPE
	ENTERPRISE	tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a major alarm clears."
	::= 13

tmonMNalarmSet TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a minor alarm is set."
	::= 14

tmonMNalarmClr TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a minor alarm clears."
	::= 15

tmonSTalarmSet TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a status alarm is set."
	::= 16

tmonSTalarmClr TRAP-TYPE
	ENTERPRISE  tmonXM
	VARIABLES {	tmonASite, tmonADesc, tmonAState, tmonASeverity, tmonAChgDate,
					tmonAChgTime, tmonAAuxDesc, tmonADispDesc, tmonAPntType,
					tmonAPort, tmonAAddress, tmonADisplay, tmonAPoint, tmonCEvent,
               tmonAIPAddr, tmonADevDesc }
	DESCRIPTION "Generated when a status alarm clears."
	::= 17

dpsRTUPointSet TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
					dpsRTUAPort, dpsRTUAAddress, dpsRTUADisplay, dpsRTUAPoint,
					dpsRTUAPntDesc, dpsRTUAState }
	DESCRIPTION "Generated when a point is set."
	::= 20

dpsRTUPointClr TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
					dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
					dpsRTUAPntDesc, dpsRTUAState }
	DESCRIPTION "Generated when a point clears."
	::= 21

dpsRTUsumPSet TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime }
	DESCRIPTION "Generated when any point is set."
	::= 101

dpsRTUsumPClr TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime }
	DESCRIPTION "Generated when all points clear."
	::= 102

dpsRTUcomFailed TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime }
	DESCRIPTION "Generated when polled unit fails to respond."
	::= 103

dpsRTUcomRestored TRAP-TYPE
	ENTERPRISE  dpsRTU
	VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime }
	DESCRIPTION "Generated when failed unit resumes responding."
	::= 104

-- **************************************************************************
-- Granular TRAP definitions
--
--    The following section supports granular trapping available on selected
-- DPS remote telemetry units.  This software selectable facility changes the
-- trap sent by a remote so equipped.  The standard trap identifies a SET or
-- CLR event in the trap ID and binds variables identifying the specific
-- remote point associated with the event.  A granular trap identifies a SET
-- or CLR event and the specific point associated with the event all in the
-- trap ID.  This is accomplished by mapping all SET event/points into the
-- trap ID range 10001-19999 and all CLR event/points into the trap ID range
-- 20001-29999.
--    If the unit manages multiple displays, the displays are mapped
-- sequentially with each display occupying a 64 point range.  For example, a
-- standalone standard or timestamp KDA which manages two displays, reports
-- SET event/points in the first display (discrete alarm points) in the range
-- 10001-10064.  The CLR event/points for the same display would be reported
-- in the range 20001-20064.  The second display (controls & housekeeping
-- alarm points) would have its SET event/points reported in the range 10065-
-- 10128 and its CLR event/points reported in the range 20065-20128.
--    SET and CLR definitions for the first 64 points have been included and
-- can be used as is for driving most SNMP manager mechanisms designed to key
-- on the trap ID for distinguishing and managing events.  Additional events
-- can be added simply by editing the following trap definitions prior to
-- compiling this file into your SNMP manager.  We recommend managing the SET
-- and CLR event definitions for a specific point as a single unit and using
-- the following simple rules:
--  + Adjust the numeric portion of the label preceeding TRAP-TYPE.
--  + Adjust the numeric reference in the DESCRIPTION text.
--  + Adjust the number on the last line of the definition.
--
--    Using these rules a definition for the 65th point would be:
-- 
-- dpsRTUp0065Set TRAP-TYPE
-- 	ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when granular point 65 is set."
--    ::= 10065
--
-- dpsRTUp0065Clr TRAP-TYPE
--    ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when granular point 65 clears."
--    ::= 20065
--
--    This editing can can be accomplished quite easily using a plain ASCII
-- file editor.  The repetitive structure of the definitions also makes for
-- rapid scripted or programmed generation if any such tools are available.
-- A compressed file containing event/point definitions for 144 displays is
-- available (DPS_G36.zip 150K) which uncompressed (DPS_G36.mib 6.2M) can be
-- used for cut-and-paste editing if desired.
--    The definitions can be further customized if desired by similar editing
-- prior to compiling carefully observing the following conventions:
--  + The label preceeding the TRAP-TYPE designator can be edited with some
--    freedom but the label must be utterly unique among all trap definitions.
--  + The ENTERPRISE and VARIABLES sections must not be changed.
--  + The DESCRIPTION can be edited with complete freedom and is typically
--    ignored within the context of standard SNMP manager trap handling.  The
--    quote mark before and after the text of the description are required.
--  + The number on the last line of the definition is the actual trap ID
--    defined and must also be utterly unique.
--
--    For example:
-- 
-- dpsRTUp0001Set TRAP-TYPE
-- 	ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when granular point 1 is set."
--    ::= 10001
--
-- dpsRTUp0001Clr TRAP-TYPE
--    ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when granular point 1 clears."
--    ::= 20001
--
--    Could be customized as:
--
-- dpsRTUFireAlarm TRAP-TYPE
--    ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when smoke detector activates."
--    ::= 10001
--
-- dpsRTUFireOut TRAP-TYPE
--    ENTERPRISE  dpsRTU
--		VARIABLES {	sysDescr, sysLocation, dpsRTUDateTime,
--						dpsRTUAPort, dpsRTUCAddress, dpsRTUADisplay, dpsRTUAPoint,
--						dpsRTUAPntDesc, dpsRTUAState }
--    DESCRIPTION "Generated when smoke detector deactivates."
--    ::= 20001
-- **************************************************************************


END