-- * Description:   Implements definitions for the Optical Amplifiers
-- *
-- * Note:          This specification is written for the new high power optical anplifiers,
-- *                but is intended to represent all new optical amplifiers in the future !!!
-- *                That is why a superset of all optical amplifier features is specified here.
-- *
-- * Copyright 2007 by BKtel communications GmbH
-- *
-- * V.0.1  23.03.2007  M. Heldmann    first draft
-- * V.0.2  25.04.2007  M. Heldmann    some items added to oaDisplayTable
-- * V.0.3  01.06.2007  M. Heldmann    changed oaStatesTecHeatHigh to oaStatesTecCurrentLow
-- *                                   and oaStatesTecCoolHigh to oaStatesTecCurrentHigh
-- * V.0.4  12.09.2007  M. Heldmann    adjusted 'LaserFeatures' type strings 
-- *                                   (max. stringsize less than 64 characters)
-- * V.0.5  04.04.2008  M. Heldmann    oaReturnLossLoLo..oaReturnLossHiHi made read-write 
-- *                                   (same behaviour as in web-interface)
-- * V.0.6  22.03.2013  M. Heldmann    added raman-type amplifier extensions 
-- *                                   oaStatesRamanBackReflectionRatio, oaStatesRamanOscSignalMissing
-- *                                   and oaDisplayAmplifierIsRamanType
-- * V.0.7  11.07.2013  M. Heldmann    adjusted syntax of "CommonEntry" to remove MIB compiler warnings
-- * V.0.8  06.05.2014  M. Heldmann    marked all internal voltage parameters as 'optional'
-- * V.0.9  05.09.2014  M. Heldmann    changed CommonModuleWidth and ConfigNESlotWrite STATUS to optional
-- *********************************************************************************************


BKTEL-HFC862-OA-V01-MIB DEFINITIONS ::= BEGIN

    IMPORTS
        OBJECT-TYPE
                 FROM RFC-1212
        modules, DisplayString, TruthValue, PerceivedSeverityValue, NESlotValue, ModuleWidthValue
                 FROM BKTEL-HFC862-BASE-MIB
    ;

    oa                 OBJECT IDENTIFIER ::= { modules 116 }
    oaCommon           OBJECT IDENTIFIER ::= { oa 1 }
    oaStates           OBJECT IDENTIFIER ::= { oa 2 }
    oaConfiguration    OBJECT IDENTIFIER ::= { oa 3 }
    oaControl          OBJECT IDENTIFIER ::= { oa 4 }
    oaMeasuringValues  OBJECT IDENTIFIER ::= { oa 5 }
    oaDisplay          OBJECT IDENTIFIER ::= { oa 6 }


--
-- Type definitions
--


    RegulationMode ::= INTEGER
        {
        regModeConstantOutputPower(1),
        regModeConstantGain(2)
        }

    SbsEvaluationMode ::= INTEGER
        {
        evalModeDefault(1),
        evalModeFullScan(2)
        }

    SbsEvaluationState ::= INTEGER
        {
        evaluationNotSupported(1),
        evaluationDone(2),
        evaluationInProgress(3),
        evaluationFailed(4)
        }

    ExtIOmode ::= INTEGER
        {
        modeActiveLowOutput(1),
        modeActiveHighOutput(2),
        modeRedundantMasterIrreversible(3),
        modeRedundantMasterFallback(4),
        modeRedundantSlave(5)
        }

    ExtIOmask ::= INTEGER
        {
        maskAlarmsOnly(1),
        maskAlarmsAndWarnings(2),
        maskSpecial(3)           -- This item is NOT writable !!
        }

    LaserFeatures ::= INTEGER
        {
        lasNonExistent(0),
        lasCurrent(1),
        lasCurrentLasTec(3),
        lasCurrentLasTemperature(5),
        lasCurrentLasTecLasTemperature(7),
        lasCurrentLasVoltage(9),
        lasCurrentLasTecLasVoltage(11),
        lasCurrentLasTemperatureLasVoltage(13),
        lasCurrentLasTecLasTemperatureLasVoltage(15),
        lasCurrentLasPumpPower(17),
        lasCurrentLasTecLasPumpPower(19),
        lasCurrentLasTemperatureLasPumpPower(21),
        lasCurrentLasTecLasTemperatureLasPumpPower(23),
        lasCurrentLasVoltageLasPumpPower(25),
        lasCurrentLasTecLasVoltageLasPumpPower(27),
        lasCurrentLasTemperatureLasVoltageLasPumpPower(29),
        lasCurrentLasTecLasTemperatureLasVoltageLasPumpPower(31)
        }

    NESlotWriteValue ::= INTEGER (-1..99)


-- MibCompiler defs --
-- $idx$: InternalVoltage
-- $idx$: Laser
-- MibCompiler defs --

--*****************************************************************************************
-- OA ( Optical Amplifier)

--*****************************************************************************************
-- oaCommon group

    oaCommonNumberOfModules OBJECT-TYPE
        SYNTAX  INTEGER(0..50)
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Number of modules in table."
    ::= { oaCommon 1 }

    oaCommonTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaCommonEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION "The table contains all modules of the OA-type in the NE"
    ::= { oaCommon 2 }

-- table of states entry(ro/rw)

    oaCommonEntry OBJECT-TYPE
        SYNTAX OaCommonEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION "Common-Values for a module."
        INDEX { oaNESlot }
    ::= { oaCommonTable 1 }

-- the structure of the entry

    OaCommonEntry ::= SEQUENCE
    {
        oaNESlot                      NESlotValue,
        oaCommonType                  DisplayString,
        oaCommonDescr                 DisplayString,
        oaCommonFirmwareId            DisplayString,
        oaCommonModuleWidth           ModuleWidthValue
    }

    oaNESlot OBJECT-TYPE
        SYNTAX  NESlotValue
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "The slot number of the chassis for which this
        entry contains management information."
    ::= { oaCommonEntry 1 }

    oaCommonType OBJECT-TYPE
        SYNTAX  DisplayString  (SIZE(0..32))
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
        "The type of physical module. modSlotEmpty indicates
         an empty slot.  A Value of modSlotUnknown indicates
         that the type of module is unknown."
    ::= { oaCommonEntry 2 }

    oaCommonDescr OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
        "A textual description of the module.
        If not available, this Value should be
        set to a zero length string."
    ::= { oaCommonEntry 3 }

    oaCommonFirmwareId OBJECT-TYPE
        SYNTAX DisplayString (SIZE(0..32))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The firmware Id of the module."
    ::= { oaCommonEntry 4 }

    oaCommonModuleWidth OBJECT-TYPE
        SYNTAX ModuleWidthValue
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The width of the module in multiples of slots (1, 2, ...)"
    ::= { oaCommonEntry 5 }

--*****************************************************************************************
-- oaMeasuringValues group
--
-- !!! NOTE !!!
--
--      Measuring values in this table that are not supported by the device
--      return zero for the value and its limits.

-- table of measuring Values

    oaMeasuringValuesTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaMeasuringValuesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
   ::= { oaMeasuringValues 1 }

-- table of measuring Values entry

    oaMeasuringValuesEntry OBJECT-TYPE
        SYNTAX OaMeasuringValuesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION "Common-Values for a module."
        INDEX { oaNESlot }
  ::= { oaMeasuringValuesTable 1 }

--  the structure of the entry

    OaMeasuringValuesEntry ::= SEQUENCE
    {
        oaTemperatureLoLo              INTEGER,
        oaTemperatureLo                INTEGER,
        oaTemperatureValue             INTEGER,
        oaTemperatureHi                INTEGER,
        oaTemperatureHiHi              INTEGER,

        oaInputPowerLoLo               INTEGER,
        oaInputPowerLo                 INTEGER,
        oaInputPowerValue              INTEGER,
        oaInputPowerHi                 INTEGER,
        oaInputPowerHiHi               INTEGER,

        oaOutputPwrOrGainLoLo          INTEGER,
        oaOutputPwrOrGainLo            INTEGER,
        oaOutputPwrOrGainValue         INTEGER,
        oaOutputPwrOrGainHi            INTEGER,
        oaOutputPwrOrGainHiHi          INTEGER,

        oaReturnLossLoLo               INTEGER,
        oaReturnLossLo                 INTEGER,
        oaReturnLossValue              INTEGER,
        oaReturnLossHi                 INTEGER,
        oaReturnLossHiHi               INTEGER,

        oaInputVoltageLoLo             INTEGER,
        oaInputVoltageLo               INTEGER,
        oaInputVoltageValue            INTEGER,
        oaInputVoltageHi               INTEGER,
        oaInputVoltageHiHi             INTEGER,

        oaInternalVoltage1LoLo         INTEGER,
        oaInternalVoltage1Lo           INTEGER,
        oaInternalVoltage1Value        INTEGER,
        oaInternalVoltage1Hi           INTEGER,
        oaInternalVoltage1HiHi         INTEGER,

        oaInternalVoltage2LoLo         INTEGER,
        oaInternalVoltage2Lo           INTEGER,
        oaInternalVoltage2Value        INTEGER,
        oaInternalVoltage2Hi           INTEGER,
        oaInternalVoltage2HiHi         INTEGER,

        oaInternalVoltage3LoLo         INTEGER,
        oaInternalVoltage3Lo           INTEGER,
        oaInternalVoltage3Value        INTEGER,
        oaInternalVoltage3Hi           INTEGER,
        oaInternalVoltage3HiHi         INTEGER,

        -- ***

        oaLaser1CurrentRelLoLo         INTEGER,
        oaLaser1CurrentRelLo           INTEGER,
        oaLaser1CurrentRelValue        INTEGER,
        oaLaser1CurrentRelHi           INTEGER,
        oaLaser1CurrentRelHiHi         INTEGER,

        oaLaser1TecRelLoLo             INTEGER,
        oaLaser1TecRelLo               INTEGER,
        oaLaser1TecRelValue            INTEGER,
        oaLaser1TecRelHi               INTEGER,
        oaLaser1TecRelHiHi             INTEGER,

        oaLaser1TemperatureLoLo        INTEGER,
        oaLaser1TemperatureLo          INTEGER,
        oaLaser1TemperatureValue       INTEGER,
        oaLaser1TemperatureHi          INTEGER,
        oaLaser1TemperatureHiHi        INTEGER,

        oaLaser1VoltageLoLo            INTEGER,
        oaLaser1VoltageLo              INTEGER,
        oaLaser1VoltageValue           INTEGER,
        oaLaser1VoltageHi              INTEGER,
        oaLaser1VoltageHiHi            INTEGER,

        -- ***

        oaLaser2CurrentRelLoLo         INTEGER,
        oaLaser2CurrentRelLo           INTEGER,
        oaLaser2CurrentRelValue        INTEGER,
        oaLaser2CurrentRelHi           INTEGER,
        oaLaser2CurrentRelHiHi         INTEGER,

        oaLaser2TecRelLoLo             INTEGER,
        oaLaser2TecRelLo               INTEGER,
        oaLaser2TecRelValue            INTEGER,
        oaLaser2TecRelHi               INTEGER,
        oaLaser2TecRelHiHi             INTEGER,

        oaLaser2TemperatureLoLo        INTEGER,
        oaLaser2TemperatureLo          INTEGER,
        oaLaser2TemperatureValue       INTEGER,
        oaLaser2TemperatureHi          INTEGER,
        oaLaser2TemperatureHiHi        INTEGER,

        oaLaser2VoltageLoLo            INTEGER,
        oaLaser2VoltageLo              INTEGER,
        oaLaser2VoltageValue           INTEGER,
        oaLaser2VoltageHi              INTEGER,
        oaLaser2VoltageHiHi            INTEGER,

        -- ***

        oaLaser3CurrentRelLoLo         INTEGER,
        oaLaser3CurrentRelLo           INTEGER,
        oaLaser3CurrentRelValue        INTEGER,
        oaLaser3CurrentRelHi           INTEGER,
        oaLaser3CurrentRelHiHi         INTEGER,

        oaLaser3TecRelLoLo             INTEGER,
        oaLaser3TecRelLo               INTEGER,
        oaLaser3TecRelValue            INTEGER,
        oaLaser3TecRelHi               INTEGER,
        oaLaser3TecRelHiHi             INTEGER,

        oaLaser3TemperatureLoLo        INTEGER,
        oaLaser3TemperatureLo          INTEGER,
        oaLaser3TemperatureValue       INTEGER,
        oaLaser3TemperatureHi          INTEGER,
        oaLaser3TemperatureHiHi        INTEGER,

        oaLaser3VoltageLoLo            INTEGER,
        oaLaser3VoltageLo              INTEGER,
        oaLaser3VoltageValue           INTEGER,
        oaLaser3VoltageHi              INTEGER,
        oaLaser3VoltageHiHi            INTEGER,

        -- ***

        oaLaser4CurrentRelLoLo         INTEGER,
        oaLaser4CurrentRelLo           INTEGER,
        oaLaser4CurrentRelValue        INTEGER,
        oaLaser4CurrentRelHi           INTEGER,
        oaLaser4CurrentRelHiHi         INTEGER,

        oaLaser4TecRelLoLo             INTEGER,
        oaLaser4TecRelLo               INTEGER,
        oaLaser4TecRelValue            INTEGER,
        oaLaser4TecRelHi               INTEGER,
        oaLaser4TecRelHiHi             INTEGER,

        oaLaser4TemperatureLoLo        INTEGER,
        oaLaser4TemperatureLo          INTEGER,
        oaLaser4TemperatureValue       INTEGER,
        oaLaser4TemperatureHi          INTEGER,
        oaLaser4TemperatureHiHi        INTEGER,

        oaLaser4VoltageLoLo            INTEGER,
        oaLaser4VoltageLo              INTEGER,
        oaLaser4VoltageValue           INTEGER,
        oaLaser4VoltageHi              INTEGER,
        oaLaser4VoltageHiHi            INTEGER,

        -- ***

        oaLaser5CurrentRelLoLo         INTEGER,
        oaLaser5CurrentRelLo           INTEGER,
        oaLaser5CurrentRelValue        INTEGER,
        oaLaser5CurrentRelHi           INTEGER,
        oaLaser5CurrentRelHiHi         INTEGER,

        oaLaser5TecRelLoLo             INTEGER,
        oaLaser5TecRelLo               INTEGER,
        oaLaser5TecRelValue            INTEGER,
        oaLaser5TecRelHi               INTEGER,
        oaLaser5TecRelHiHi             INTEGER,

        oaLaser5TemperatureLoLo        INTEGER,
        oaLaser5TemperatureLo          INTEGER,
        oaLaser5TemperatureValue       INTEGER,
        oaLaser5TemperatureHi          INTEGER,
        oaLaser5TemperatureHiHi        INTEGER,

        oaLaser5VoltageLoLo            INTEGER,
        oaLaser5VoltageLo              INTEGER,
        oaLaser5VoltageValue           INTEGER,
        oaLaser5VoltageHi              INTEGER,
        oaLaser5VoltageHiHi            INTEGER,

        -- ***

        oaLaser6CurrentRelLoLo         INTEGER,
        oaLaser6CurrentRelLo           INTEGER,
        oaLaser6CurrentRelValue        INTEGER,
        oaLaser6CurrentRelHi           INTEGER,
        oaLaser6CurrentRelHiHi         INTEGER,

        oaLaser6TecRelLoLo             INTEGER,
        oaLaser6TecRelLo               INTEGER,
        oaLaser6TecRelValue            INTEGER,
        oaLaser6TecRelHi               INTEGER,
        oaLaser6TecRelHiHi             INTEGER,

        oaLaser6TemperatureLoLo        INTEGER,
        oaLaser6TemperatureLo          INTEGER,
        oaLaser6TemperatureValue       INTEGER,
        oaLaser6TemperatureHi          INTEGER,
        oaLaser6TemperatureHiHi        INTEGER,

        oaLaser6VoltageLoLo            INTEGER,
        oaLaser6VoltageLo              INTEGER,
        oaLaser6VoltageValue           INTEGER,
        oaLaser6VoltageHi              INTEGER,
        oaLaser6VoltageHiHi            INTEGER
    }

-- *****
    oaTemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The module temperature low alarm threshold in steps of 0.1 celsius degrees."
    ::= { oaMeasuringValuesEntry 1 }

    oaTemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The module temperature low warning threshold in steps of 0.1 celsius degrees."
    ::= { oaMeasuringValuesEntry 2 }

    oaTemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The module temperature in steps of 0.1 celsius degrees."
    ::= { oaMeasuringValuesEntry 3 }

    oaTemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The module temperature high warning threshold in steps of 0.1 celsius degrees."
    ::= { oaMeasuringValuesEntry 4 }

    oaTemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The module temperature high alarm threshold in steps of 0.1 celsius degrees."
    ::= { oaMeasuringValuesEntry 5 }

-- *****
    oaInputPowerLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Input power low alarm threshold in steps of 0.1dBm."
    ::= { oaMeasuringValuesEntry 6 }

    oaInputPowerLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Input power low warning threshold in steps of 0.1dBm."
    ::= { oaMeasuringValuesEntry 7 }

    oaInputPowerValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Input power in steps of 0.1dBm."
    ::= { oaMeasuringValuesEntry 8 }

    oaInputPowerHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Input power high warning threshold in steps of 0.1dBm."
    ::= { oaMeasuringValuesEntry 9 }

    oaInputPowerHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Input power high alarm threshold in steps of 0.1dBm."
    ::= { oaMeasuringValuesEntry 10 }

-- *****
    oaOutputPwrOrGainLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Output power (or gain) low alarm threshold in steps of 0.1dB(m).
                     See oaConfigRegulationMode variable too"
    ::= { oaMeasuringValuesEntry 11 }

    oaOutputPwrOrGainLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Output power (or gain) low warning threshold in steps of 0.1dB(m).
                     See oaConfigRegulationMode variable too"
    ::= { oaMeasuringValuesEntry 12 }

    oaOutputPwrOrGainValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Output power (or gain) in steps of 0.1dB(m).
                     See oaConfigRegulationMode variable too"
    ::= { oaMeasuringValuesEntry 13 }

    oaOutputPwrOrGainHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Output power (or gain) high warning threshold in steps of 0.1dB(m).
                     See oaConfigRegulationMode variable too"
    ::= { oaMeasuringValuesEntry 14 }

    oaOutputPwrOrGainHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Output power (or gain) high alarm threshold in steps of 0.1dB(m).
                     See oaConfigRegulationMode variable too"
    ::= { oaMeasuringValuesEntry 15 }

-- *****
    oaReturnLossLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "ReturnLoss low alarm threshold in steps of 0.1 dB."
    ::= { oaMeasuringValuesEntry 16 }

    oaReturnLossLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "ReturnLoss low warning threshold in steps of 0.1 dB."
    ::= { oaMeasuringValuesEntry 17 }

    oaReturnLossValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "ReturnLoss in steps of 0.1 dB."
    ::= { oaMeasuringValuesEntry 18 }

    oaReturnLossHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "ReturnLoss high warning threshold in steps of 0.1 dB."
    ::= { oaMeasuringValuesEntry 19 }

    oaReturnLossHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "ReturnLoss  high alarm threshold in steps of 0.1 dB."
    ::= { oaMeasuringValuesEntry 20 }

-- *****
    oaInputVoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The input supply voltage low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 21 }

    oaInputVoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The input supply voltage low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 22 }

    oaInputVoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The input supply voltage in steps of 0.1 Volts.
                     Input supply voltage nominal value, see 'oaDisplayInputVoltageNominal'"
    ::= { oaMeasuringValuesEntry 23 }

    oaInputVoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The input supply voltage high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 24 }

    oaInputVoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The input supply voltage high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 25 }

-- #####+20 Space reserved for 4 additional measuring values with limits

-- ########################### Internal Voltages Section ##################################

-- *****
    oaInternalVoltage1LoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 46 }

    oaInternalVoltage1Lo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 47 }

    oaInternalVoltage1Value OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage in steps of 0.1 Volts.
                     Internal voltage nominal value, see 'oaDisplayInternalVoltage1Nominal'"
    ::= { oaMeasuringValuesEntry 48 }

    oaInternalVoltage1Hi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 49 }

    oaInternalVoltage1HiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 50 }

-- *****
    oaInternalVoltage2LoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 51 }

    oaInternalVoltage2Lo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 52 }

    oaInternalVoltage2Value OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage in steps of 0.1 Volts.
                     Internal voltage nominal value, see 'oaDisplayInternalVoltage2Nominal'"
    ::= { oaMeasuringValuesEntry 53 }

    oaInternalVoltage2Hi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 54 }

    oaInternalVoltage2HiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 55 }

-- *****
    oaInternalVoltage3LoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 56 }

    oaInternalVoltage3Lo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 57 }

    oaInternalVoltage3Value OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage in steps of 0.1 Volts.
                     Internal voltage nominal value, see 'oaDisplayInternalVoltage3Nominal'"
    ::= { oaMeasuringValuesEntry 58 }

    oaInternalVoltage3Hi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 59 }

    oaInternalVoltage3HiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The internal voltage high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 60 }

-- #####+25 Space reserved for 5 additional internal voltage measuring values with limits

-- ################################### Lasers Section ##################################

-- ***********************************
    oaLaser1CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 86 }

    oaLaser1CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 87 }

    oaLaser1CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 88 }

    oaLaser1CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 89 }

    oaLaser1CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 90 }

-- *****
    oaLaser1TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 91 }

    oaLaser1TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 92 }

    oaLaser1TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 93 }

    oaLaser1TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 94 }

    oaLaser1TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 95 }

-- *****
    oaLaser1TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 96 }

    oaLaser1TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 97 }

    oaLaser1TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 98 }

    oaLaser1TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 99 }

    oaLaser1TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 100 }

-- *****
    oaLaser1VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 101 }

    oaLaser1VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 102 }

    oaLaser1VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 103 }

    oaLaser1VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 104 }

    oaLaser1VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 105 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits

-- ***********************************
    oaLaser2CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 111 }

    oaLaser2CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 112 }

    oaLaser2CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 113 }

    oaLaser2CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 114 }

    oaLaser2CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 115 }

-- *****
    oaLaser2TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 116 }

    oaLaser2TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 117 }

    oaLaser2TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 118 }

    oaLaser2TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 119 }

    oaLaser2TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 120 }

-- *****
    oaLaser2TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 121 }

    oaLaser2TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 122 }

    oaLaser2TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 123 }

    oaLaser2TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 124 }

    oaLaser2TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 125 }

-- *****
    oaLaser2VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 126 }

    oaLaser2VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 127 }

    oaLaser2VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 128 }

    oaLaser2VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 129 }

    oaLaser2VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 130 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits

-- ***********************************
    oaLaser3CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 136 }

    oaLaser3CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 137 }

    oaLaser3CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 138 }

    oaLaser3CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 139 }

    oaLaser3CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 140 }

-- *****
    oaLaser3TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 141 }

    oaLaser3TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 142 }

    oaLaser3TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 143 }

    oaLaser3TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 144 }

    oaLaser3TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 145 }

-- *****
    oaLaser3TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 146 }

    oaLaser3TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 147 }

    oaLaser3TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 148 }

    oaLaser3TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 149 }

    oaLaser3TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 150 }

-- *****
    oaLaser3VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 151 }

    oaLaser3VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 152 }

    oaLaser3VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 153 }

    oaLaser3VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 154 }

    oaLaser3VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 155 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits

-- ***********************************
    oaLaser4CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 161 }

    oaLaser4CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 162 }

    oaLaser4CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 163 }

    oaLaser4CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 164 }

    oaLaser4CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 165 }

-- *****
    oaLaser4TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 166 }

    oaLaser4TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 167 }

    oaLaser4TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 168 }

    oaLaser4TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 169 }

    oaLaser4TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 170 }

-- *****
    oaLaser4TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 171 }

    oaLaser4TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 172 }

    oaLaser4TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 173 }

    oaLaser4TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 174 }

    oaLaser4TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 175 }

-- *****
    oaLaser4VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 176 }

    oaLaser4VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 177 }

    oaLaser4VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 178 }

    oaLaser4VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 179 }

    oaLaser4VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 180 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits

-- ***********************************
    oaLaser5CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 186 }

    oaLaser5CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 187 }

    oaLaser5CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 188 }

    oaLaser5CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 189 }

    oaLaser5CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 190 }

-- *****
    oaLaser5TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 191 }

    oaLaser5TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 192 }

    oaLaser5TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 193 }

    oaLaser5TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 194 }

    oaLaser5TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 195 }

-- *****
    oaLaser5TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 196 }

    oaLaser5TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 197 }

    oaLaser5TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 198 }

    oaLaser5TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 199 }

    oaLaser5TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 200 }

-- *****
    oaLaser5VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 201 }

    oaLaser5VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 202 }

    oaLaser5VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 203 }

    oaLaser5VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 204 }

    oaLaser5VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 205 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits

-- ***********************************
    oaLaser6CurrentRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 211 }

    oaLaser6CurrentRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 212 }

    oaLaser6CurrentRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The laser no.1 current relative to the current at begin of life in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 213 }

    oaLaser6CurrentRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 214 }

    oaLaser6CurrentRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Relative laser no.1 current high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 215 }

-- *****
    oaLaser6TecRelLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 216 }

    oaLaser6TecRelLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 low warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 217 }

    oaLaser6TecRelValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The thermo-electric-cooler current of laser no.1 relative to its maximum value in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 218 }

    oaLaser6TecRelHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high warning threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 219 }

    oaLaser6TecRelHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Thermo-electric-cooler current of laser no.1 high alarm threshold in steps of 0.1%."
    ::= { oaMeasuringValuesEntry 220 }

-- *****
    oaLaser6TemperatureLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 221 }

    oaLaser6TemperatureLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 low warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 222 }

    oaLaser6TemperatureValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 223 }

    oaLaser6TemperatureHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high warning threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 224 }

    oaLaser6TemperatureHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Temperature of laser no.1 high alarm threshold in steps of 0.1 Celsius Degrees."
    ::= { oaMeasuringValuesEntry 225 }

-- *****
    oaLaser6VoltageLoLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 226 }

    oaLaser6VoltageLo OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 low warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 227 }

    oaLaser6VoltageValue OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 228 }

    oaLaser6VoltageHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high warning threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 229 }

    oaLaser6VoltageHiHi OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-only
        STATUS optional
        DESCRIPTION "The supply voltage of laser no.1 high alarm threshold in steps of 0.1 Volts."
    ::= { oaMeasuringValuesEntry 230 }

-- #####+5 Space reserved for 1 additional laser measuring value with limits


--*****************************************************************************************
--  oaStates group

    oaStatesTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaStatesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
    ::= { oaStates 1 }

-- table of states entry(ro/rw)

    oaStatesEntry OBJECT-TYPE
        SYNTAX OaStatesEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION "Alarms for a module."
        INDEX { oaNESlot }
    ::= { oaStatesTable 1 }

-- the structure of the entry

    OaStatesEntry ::= SEQUENCE
    {
        oaStatesBootloader               PerceivedSeverityValue,
        oaStatesCommLoss                 PerceivedSeverityValue,
        oaStatesInitializing             PerceivedSeverityValue,
        oaStatesLaserShutdown            PerceivedSeverityValue,
        oaStatesTemperatureLow           PerceivedSeverityValue,
        oaStatesTemperatureHigh          PerceivedSeverityValue,
        oaStatesSystem                   PerceivedSeverityValue,
        oaStatesInputPwrLow              PerceivedSeverityValue,
        oaStatesInputPwrHigh             PerceivedSeverityValue,
        oaStatesOutputPwrOrGainLow       PerceivedSeverityValue,
        oaStatesOutputPwrOrGainHigh      PerceivedSeverityValue,
        oaStatesReturnLossLow            PerceivedSeverityValue,
        oaStatesReturnLossHigh           PerceivedSeverityValue,
        oaStatesRedundancySwitch         PerceivedSeverityValue,
        oaStatesInputVoltageLow          PerceivedSeverityValue,
        oaStatesInputVoltageHigh         PerceivedSeverityValue,
        -- ** Only for 19 inch devices with supply and fan units
        oaStatesPowerSupplyLeft          PerceivedSeverityValue,
        oaStatesPowerSupplyRight         PerceivedSeverityValue,
        oaStatesFanLeft                  PerceivedSeverityValue,
        oaStatesFanRight                 PerceivedSeverityValue,
        -- ** Shared alarms for all internal voltages
        oaStatesInternalVoltageLow       PerceivedSeverityValue,
        oaStatesInternalVoltageHigh      PerceivedSeverityValue,
        -- ** Shared alarms for all laser parameters
        oaStatesLaserCurrentLow          PerceivedSeverityValue,
        oaStatesLaserCurrentHigh         PerceivedSeverityValue,
        oaStatesTecCurrentLow            PerceivedSeverityValue,
        oaStatesTecCurrentHigh           PerceivedSeverityValue,
        oaStatesLaserTempLow             PerceivedSeverityValue,
        oaStatesLaserTempHigh            PerceivedSeverityValue,
        oaStatesLaserVoltageLow          PerceivedSeverityValue,
        oaStatesLaserVoltageHigh         PerceivedSeverityValue,
        -- ** Only for amplifiers of raman type (see oaDisplayAmplifierIsRamanType) - 
        oaStatesRamanBackReflectionRatio PerceivedSeverityValue,
        oaStatesRamanOscSignalMissing    PerceivedSeverityValue
    }

    oaStatesBootloader OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The device is running in bootloader mode
             without a legal application software."
    ::= { oaStatesEntry 1 }

    oaStatesCommLoss OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The NEC has lost the connection to the device.
             Reason may be a removed or defective device.
             Note that this state is set by the NEC and not
             by the device"
    ::= { oaStatesEntry 2 }

    oaStatesInitializing OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The device is initializing"
    ::= { oaStatesEntry 3 }

    oaStatesLaserShutdown OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Lasers are shutdown, no optical output"
    ::= { oaStatesEntry 4 }

    oaStatesTemperatureLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Device internal temperature low"
    ::= { oaStatesEntry 5 }

    oaStatesTemperatureHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Device internal temperature high"
    ::= { oaStatesEntry 6 }

    oaStatesSystem OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Internal error occured"
    ::= { oaStatesEntry 7 }

    oaStatesInputPwrLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Optical input power low"
    ::= { oaStatesEntry 8 }

    oaStatesInputPwrHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Optical input power high"
    ::= { oaStatesEntry 9 }

    oaStatesOutputPwrOrGainLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Optical output power (or gain) low"
    ::= { oaStatesEntry 10 }

    oaStatesOutputPwrOrGainHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Optical output power (or gain) high"
    ::= { oaStatesEntry 11 }

    oaStatesReturnLossLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Return loss low"
    ::= { oaStatesEntry 12 }

    oaStatesReturnLossHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Return loss high"
    ::= { oaStatesEntry 13 }

    oaStatesRedundancySwitch OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "This (redundant) device has been activated (redundancy switchover)"
    ::= { oaStatesEntry 14 }

    oaStatesInputVoltageLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Input supply voltage low"
    ::= { oaStatesEntry 15 }

    oaStatesInputVoltageHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Input supply voltage high"
    ::= { oaStatesEntry 16 }

-- #####+8 Space reserved for additional states

    oaStatesPowerSupplyLeft OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The left (looking from front) power supply unit fails.
                     Only valid for devices in 19 inch housing"
    ::= { oaStatesEntry 25 }

    oaStatesPowerSupplyRight OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The right (looking from front) power supply unit fails.
                     Only valid for devices in 19 inch housing"
    ::= { oaStatesEntry 26 }

    oaStatesFanLeft OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The left (looking from front) fan unit fails.
                     Only valid for devices in 19 inch housing"
    ::= { oaStatesEntry 27 }

    oaStatesFanRight OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "The right (looking from front) fan unit fails.
                     Only valid for devices in 19 inch housing"
    ::= { oaStatesEntry 28 }

    oaStatesInternalVoltageLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "One (or more) internal voltages low"
    ::= { oaStatesEntry 29 }

    oaStatesInternalVoltageHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "One (or more) internal voltages high"
    ::= { oaStatesEntry 30 }

    oaStatesLaserCurrentLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser current of one (or more) lasers low"
    ::= { oaStatesEntry 31 }

    oaStatesLaserCurrentHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser current of one (or more) lasers high (laser is aging)"
    ::= { oaStatesEntry 32 }

    oaStatesTecCurrentLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser TEC current limit of one (or more) lasers reached (heating limit)"
    ::= { oaStatesEntry 33 }

    oaStatesTecCurrentHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser TEC current limit of one (or more) lasers reached (cooling limit)"
    ::= { oaStatesEntry 34 }

    oaStatesLaserTempLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser temperature of one (or more) lasers low"
    ::= { oaStatesEntry 35 }

    oaStatesLaserTempHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser temperature of one (or more) lasers high"
    ::= { oaStatesEntry 36 }

    oaStatesLaserVoltageLow OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser voltage supply of one (or more) lasers low"
    ::= { oaStatesEntry 37 }

    oaStatesLaserVoltageHigh OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Laser voltage supply of one (or more) lasers high"
    ::= { oaStatesEntry 38 }

    oaStatesRamanBackReflectionRatio OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Raman amplifier back reflection ratio high alarm
                     Only used if oaDisplayAmplifierIsRamanType == true(1)"
    ::= { oaStatesEntry 39 }

    oaStatesRamanOscSignalMissing OBJECT-TYPE
        SYNTAX PerceivedSeverityValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Raman amplifier oscillator signal missing alarm
                     Only used if oaDisplayAmplifierIsRamanType == true(1)"
    ::= { oaStatesEntry 40 }

--*****************************************************************************************
--  oaControl group

    oaControlTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
    ::= { oaControl 1 }

-- table of control entry(ro/rw)

    oaControlEntry OBJECT-TYPE
        SYNTAX OaControlEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION "Alarms for a module."
        INDEX { oaNESlot }
    ::= { oaControlTable 1 }

-- the structure of the entry

    OaControlEntry ::= SEQUENCE
    {
        oaControlLaserShutdown                     TruthValue,
        oaControlReset                             TruthValue,
        oaControlModuleLedBlink                    TruthValue,
        oaControlSbsEvaluationStart                TruthValue
    }

    oaControlLaserShutdown OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Shutdown the laser(s), optical power on/off."
    ::= { oaControlEntry 1 }

    oaControlReset OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION "Reset the module."
    ::= { oaControlEntry 2 }

    oaControlModuleLedBlink OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION   "Writing this variable to true(1) lets the device's
        modul LED blink green for 10 seconds.
        Writing this variable to false(2) stops blinking at once.
        This variable always returns false(2) on read requests"
    ::= { oaControlEntry 3 }

    oaControlSbsEvaluationStart OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "Setting to true(1) starts an SBS threshold evaluation process.
             Always reads as false(2)"
    ::={ oaControlEntry 4 }


--*****************************************************************************************
-- oaConfiguration group

    oaConfigurationTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaConfigurationEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
    ::= { oaConfiguration 1 }

-- table of configuration entry(ro/rw)

    oaConfigurationEntry OBJECT-TYPE
        SYNTAX OaConfigurationEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
        INDEX { oaNESlot  }
    ::= { oaConfigurationTable 1 }

-- the structure of the entry

    OaConfigurationEntry ::= SEQUENCE
    {
        oaConfigNESlotWrite                     NESlotWriteValue,
        oaConfigRegulationMode                  RegulationMode,
        oaConfigOutputPwrOrGainAdjust           INTEGER,
        oaConfigModeExtIO                       ExtIOmode,
        oaConfigMaskExtIO                       ExtIOmask,
        oaConfigSbsEvaluationMode               SbsEvaluationMode
    }

    oaConfigNESlotWrite OBJECT-TYPE
        SYNTAX NESlotWriteValue
        ACCESS read-write
        STATUS optional
        DESCRIPTION "By writing this variable a slot can be assigned
            for devices that dont support hardware slot detection.
            Reading '-1' means that the slot position is NOT writable."
    ::= { oaConfigurationEntry 1 }

    oaConfigRegulationMode OBJECT-TYPE
        SYNTAX  RegulationMode
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "The regulation mode of the device.
             - regModeConstantOutputPower(1):
               If the device runs in constant output power mode, then all *OutputPwrOrGain*
               variables are interpreted as 'Output Power' specific.
             - regModeConstantGain(2):
               If the device runs in constant gain mode, then all *OutputPwrOrGain*
               variables are interpreted as 'Gain' specific."
    ::={ oaConfigurationEntry 2 }

    oaConfigOutputPwrOrGainAdjust OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-write
        STATUS  mandatory
        DESCRIPTION
            "This variable can be used to adjust the desired output power (or gain)
             value in 0.1 dB units relative to its nominal level.
             See oaConfigRegulationMode variable too"
    ::={ oaConfigurationEntry 3 }

    oaConfigModeExtIO OBJECT-TYPE
        SYNTAX ExtIOmode
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION   "The mode and usage of the device's external IO port."
    ::= { oaConfigurationEntry 4 }

    oaConfigMaskExtIO OBJECT-TYPE
        SYNTAX ExtIOmask
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
          "The alarm/warning mask that activates the device's external IO port."
    ::= { oaConfigurationEntry 5 }

    oaConfigSbsEvaluationMode OBJECT-TYPE
        SYNTAX SbsEvaluationMode
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "The SBS threshold evaluation mode."
    ::={ oaConfigurationEntry 6 }

--*****************************************************************************************
-- Display group

    oaDisplayTable OBJECT-TYPE
        SYNTAX SEQUENCE OF OaDisplayEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
    ::= { oaDisplay 1 }

-- table of configuration entry(ro/rw)

    oaDisplayEntry OBJECT-TYPE
        SYNTAX OaDisplayEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION ""
        INDEX { oaNESlot  }
    ::= { oaDisplayTable 1 }

-- the structure of the entry

    OaDisplayEntry ::= SEQUENCE
    {
        oaDisplayNumberOfLasers            INTEGER,
        oaDisplayNumberOfInternalVoltages  INTEGER,
        oaDisplayExtIOSupported            TruthValue,
        oaDisplaySbsSupported              TruthValue,
        oaDisplayReturnLossSupported       TruthValue,
        oaDisplaySbsEvaluatedThreshold     INTEGER,
        oaDisplaySbsLastEvaluationState    SbsEvaluationState,
        oaDisplaySbsLastEvaluationTime     DisplayString,
        oaDisplayOutputPwrOrGainNominal    INTEGER,
        oaDisplayOutputPwrOrGainAdjusted   INTEGER,
        oaDisplayInputVoltageNominal       INTEGER,
        oaDisplayInternalVoltage1Nominal   INTEGER,
        oaDisplayInternalVoltage2Nominal   INTEGER,
        oaDisplayInternalVoltage3Nominal   INTEGER,
        oaDisplayLaser1VoltageNominal      INTEGER,
        oaDisplayLaser2VoltageNominal      INTEGER,
        oaDisplayLaser3VoltageNominal      INTEGER,
        oaDisplayLaser4VoltageNominal      INTEGER,
        oaDisplayLaser5VoltageNominal      INTEGER,
        oaDisplayLaser6VoltageNominal      INTEGER,
        oaDisplayLaser1PumpPowerRel        INTEGER,
        oaDisplayLaser2PumpPowerRel        INTEGER,
        oaDisplayLaser3PumpPowerRel        INTEGER,
        oaDisplayLaser4PumpPowerRel        INTEGER,
        oaDisplayLaser5PumpPowerRel        INTEGER,
        oaDisplayLaser6PumpPowerRel        INTEGER,
        oaDisplayLaser1FeaturesSupported   LaserFeatures,
        oaDisplayLaser2FeaturesSupported   LaserFeatures,
        oaDisplayLaser3FeaturesSupported   LaserFeatures,
        oaDisplayLaser4FeaturesSupported   LaserFeatures,
        oaDisplayLaser5FeaturesSupported   LaserFeatures,
        oaDisplayLaser6FeaturesSupported   LaserFeatures,
        oaDisplayAmplifierIsRamanType      TruthValue
    }

    oaDisplayNumberOfLasers OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The number of lasers used by this optical amplifier"
    ::={ oaDisplayEntry 1 }

    oaDisplayNumberOfInternalVoltages OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The number of internal voltages monitored by this optical amplifier"
    ::={ oaDisplayEntry 2 }

    oaDisplayExtIOSupported OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Return 'true(1)' if external I/O feature is supported by the device."
    ::= { oaDisplayEntry 3 }

    oaDisplaySbsSupported OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Return 'true(1)' if SBS feature is supported by the device."
    ::= { oaDisplayEntry 4 }

    oaDisplayReturnLossSupported OBJECT-TYPE
        SYNTAX TruthValue
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION "Return 'true(1)' if ReturnLoss feature is supported by the device."
    ::= { oaDisplayEntry 5 }

    oaDisplaySbsEvaluatedThreshold OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The evaluated SBS output power or gain threshold in 0.1 dB(m) units.
             Not supported by all optical amplifiers"
    ::={ oaDisplayEntry 6 }

    oaDisplaySbsLastEvaluationState OBJECT-TYPE
        SYNTAX  SbsEvaluationState
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The result of last SBS threshold evaluation process.
             Returns 'evaluationNotSupported(1)' if SBS threshold evaluation
             is not supported by this optical amplifier"
    ::={ oaDisplayEntry 7 }

    oaDisplaySbsLastEvaluationTime OBJECT-TYPE
        SYNTAX  DisplayString
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The time of last successfull SBS threshold evaluation process.
             Not supported by all optical amplifiers"
    ::={ oaDisplayEntry 8 }

    oaDisplayOutputPwrOrGainNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The nominal value of output power (or gain) in 0.1 dB(m) units.
             See oaConfigRegulationMode variable too"
    ::={ oaDisplayEntry 9 }

    oaDisplayOutputPwrOrGainAdjusted OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The adjusted desired value of output power (or gain) in 0.1 dB(m) units.
             See oaConfigRegulationMode variable too"
    ::={ oaDisplayEntry 10 }

    oaDisplayInputVoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal value of input voltage in 0.1 V units."
    ::={ oaDisplayEntry 11 }

    oaDisplayInternalVoltage1Nominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal value of internal voltage no. 1 in 0.1 V units."
    ::={ oaDisplayEntry 12 }

    oaDisplayInternalVoltage2Nominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal value of internal voltage no. 2 in 0.1 V units."
    ::={ oaDisplayEntry 13 }

    oaDisplayInternalVoltage3Nominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal value of internal voltage no. 3 in 0.1 V units."
    ::={ oaDisplayEntry 14 }

-- #####+5 Space reserved for 5 additional internal voltages

    oaDisplayLaser1VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.1 in 0.1 V units."
    ::={ oaDisplayEntry 20 }

    oaDisplayLaser2VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.2 in 0.1 V units."
    ::={ oaDisplayEntry 21 }

    oaDisplayLaser3VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.3 in 0.1 V units."
    ::={ oaDisplayEntry 22 }

    oaDisplayLaser4VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.4 in 0.1 V units."
    ::={ oaDisplayEntry 23 }

    oaDisplayLaser5VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.5 in 0.1 V units."
    ::={ oaDisplayEntry 24 }

    oaDisplayLaser6VoltageNominal OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  optional
        DESCRIPTION
            "The nominal supply voltage of laser no.6 in 0.1 V units."
    ::={ oaDisplayEntry 25 }

-- #####+4 Space reserved for 4 additional lasers

    oaDisplayLaser1PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.1 in steps of 0.1%"
    ::={ oaDisplayEntry 30 }

    oaDisplayLaser2PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.2 in steps of 0.1%"
    ::={ oaDisplayEntry 31 }

    oaDisplayLaser3PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.3 in steps of 0.1%"
    ::={ oaDisplayEntry 32 }

    oaDisplayLaser4PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.4 in steps of 0.1%"
    ::={ oaDisplayEntry 33 }

    oaDisplayLaser5PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.5 in steps of 0.1%"
    ::={ oaDisplayEntry 34 }

    oaDisplayLaser6PumpPowerRel OBJECT-TYPE
        SYNTAX  INTEGER
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The pump power of laser no.6 in steps of 0.1%"
    ::={ oaDisplayEntry 35 }

-- #####+4 Space reserved for 4 additional lasers

    oaDisplayLaser1FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.1
             A bitfield containing the features supplied by this laser.
             Note that laserCurrent is always supplied."
    ::={ oaDisplayEntry 40 }

    oaDisplayLaser2FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.2"
    ::={ oaDisplayEntry 41 }

    oaDisplayLaser3FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.3"
    ::={ oaDisplayEntry 42 }

    oaDisplayLaser4FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.4"
    ::={ oaDisplayEntry 43 }

    oaDisplayLaser5FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.5"
    ::={ oaDisplayEntry 44 }

    oaDisplayLaser6FeaturesSupported OBJECT-TYPE
        SYNTAX  LaserFeatures
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION
            "The features supported by laser no.6"
    ::={ oaDisplayEntry 45 }

-- #####+4 Space reserved for 4 additional lasers

    oaDisplayAmplifierIsRamanType OBJECT-TYPE
        SYNTAX  TruthValue
        ACCESS  read-only
        STATUS  mandatory
        DESCRIPTION "Returns true(1) if this amplifier is of RAMAN type"
    ::={ oaDisplayEntry 50 }


--*****************************************************************************************
END